盐雾试验箱在电工电子、五金机械、工厂化工、船舶设备、机械产品等行业应用非常广泛,生产的盐雾试验箱使用的是国际最先进的德国造型优美,设计独特。圆弧的外形和喷塑的外壳,外观质感性强,使用的无反作用把手,使用上很容易上手,性能稳定。用户给予了非常高的评价。
我公司专业生产销售。盐雾试验箱怎么进行日常的维护和保养工作呢?
一,盐雾试验箱箱体内外部的卫生和维护1,盐雾试验箱在使用前应先把内部灰尘清扫一下。2,配电室内应该隔一段时间清洁一次,可以使用吸尘器把灰尘吸出。3,箱体外部也要每隔一段时间清洗一次,可以用抹布擦洗。
二,盐雾试验箱加湿器之检查与保养加湿器内之储水要及时更换,保持水的清洁,加湿水盘应该每月更换,让水流畅通。
三,盐雾试验箱查看超温保护器盐雾试验箱运转时,超温保护之设定最高值加20摄氏度到30摄氏度。试验箱内之温度升至超温保护之设定点时,加热器之供电即停止,"OVERHEAT"超温警示灯亮但风扇仍运转,若长时间运转及无人看管,运转前请务必确实检查超温保护器,是否设定妥当湿球超温保护器之设定为120摄氏度。
四,盐雾试验箱冷凝器灰尘的清洗办法,冷凝器应按月清洗,使用真空吸尘器把冷凝器散热网片上附着之灰尘吸除或利用高压空气喷除灰尘。
五,盐雾试验箱湿球测试布之更换当测试布表面不干净或变硬,或于做完温度控制后,继续做温湿球度控制前都必须更换测试布。测试布约三个月更换一次,更换时应用清洁布擦拭测温体,更换新测试布时应先清洗干净。 (图/文www.wxjinke.com)
英文版:Salt fog test box is widely used in electronics, hardware machinery, chemical plant, marine equipment, machinery and other industries, Wuxi salt fog test box section production is the use of the international most advanced German beautiful shape, unique design. The arc shape and the plastic shell, the appearance of the texture is strong, use without counteractive handle, the use of very easy to use, stable performance. Users are given a very high rating.
Salt fog test box how to carry out routine maintenance and maintenance work?
One, and the maintenance of salt fog test box outside the health 1, salt fog test box before using the internal dust cleaning. 2, the distribution of indoor should lie between period of time to clean, can use the vacuum cleaner to suck the dust. 3, outside the box should be cleaned once every other day, can use the cloth to scrub.
Two, salt fog test box humidifier humidifier in the inspection and maintenance of water storage to be replaced in a timely manner, and keep the water clean, water disk should be replaced every month, let the water flow.
Three, salt fog test box view over temperature protector salt fog test box operation, set the overtemperature protection of the highest value plus 20 degrees Celsius to 30 degrees celsius. Temperature test box to set the overtemperature protection point, the heater power is stopped, "OVERHEAT" over temperature warning lights but fans still running, if long time operation and unattended, please do check over temperature protection device before the operation, if properly set up the wet bulb temperature protection device is set to 120 degrees celsius.
Four, cleaning method of salt fog test box condenser dust, condenser cleaning should be on a monthly basis, using a vacuum cleaner dust attached condenser cooling mesh on the suction or by using high pressure air spray dust.
Five, salt fog test box wet ball test cloth replacement when testing the fabric surface is not clean or hardening, or to finish temperature control, temperature and wet bulb temperature control to do before must be replaced to test the cloth. The test about once every three months, and application of clean cloth to wipe the body temperature change, should be cleaned first replacement test cloth.